Industrial – Tank Repair
Brownstock Washer Seal Tank Repair
Project Description
- The existing Brownstock Washer Seal Tank had a failed FRP liner
- The tank had an unknown floor condition and an unknown foundation type
- The tank was difficult to access, and confirming these unknown conditions was not easy
- There were several non-code compliant repairs that needed to be addressed
Responsibilities:
- We reviewed the design conditions, and completed an API 620 code review and calculations
- Provided recommendations to correct issues
- We established capital cost estimates:
+/-50% and +/-25% accuracy - We prepared a repair schedule and plan
- We provided shutdown project management
- Developed a confined space ventilation plan
- Confirmation of foundation type
- Record drawings